DKWD-PURE SINGLE WAVE INVERTER B'MPPT KONTROLLUR MIBUNA
Parametru
Mudell DKWD | 70112/24 | 10212/24 | 15224/48 (152) | 20224/48 (202) | 30224/48(302) | |
Qawwa Rated | 700W | 1000W | 1500W | 2000W | 3000W | |
L-ogħla qawwa (20 ms) | 2100VA | 3000VA | 4500VA | 6000VA | 9000VA | |
Ibda bil-Mutur | 0.5HP | 1HP | 1.5HP | 2HP | 3HP | |
Vultaġġ tal-batterija | 12/24VDC | 12/24VDC | 24/48VDC | 24/48VDC | 24/48VDC | |
Max AC iċċarġjar kurrenti | 0A ~ 20A (Skond il-mudell), Il-qawwa massima tal-iċċarġjar hija 1/4 tal-qawwa nominali) | |||||
Kurrent tal-iċċarġjar tal-kontrollur solari inkorporat (mhux obbligatorju) | 10A ~ 60A (PWM jew MPPT) | 24/48V(PWM:10A~60A/MPPT:10A~100A) | ||||
Daqs (L * W * Hmm) | 340x165x283 | 410x200x350 | ||||
Daqs tal-ippakkjar (L * W * Hmm) | 405x230x340(1pc) / 475x415x350(2pc) | 475x265x410 | ||||
NW(kg) | 9.5(1pc) | 10.5(1pc) | 11.5(1pc) | 17 | 20.5 | |
GW (kg) | 11(1pc) | 12(1pc) | 13(1pc) | 19 | 22.5 | |
Metodu ta 'Installazzjoni | Torri | |||||
Mudell DKWD | 80248/96/192 | 10348/96/192 | 12396/192 | 153192 | 203192 | |
Qawwa Rated | 8KW | 10KW | 12KW | 15KW | 20KW | |
L-ogħla qawwa (20 ms) | 24KVA | 30KVA | 36KVA | 45KVA | 60KVA | |
Ibda bil-Mutur | 5HP | 7HP | 7HP | 10HP | 12HP | |
Vultaġġ tal-batterija | 48/96/192VDC | 48/96V/192VDC | 96/192VDC | 192VDC | 192VDC | |
Max AC iċċarġjar kurrenti | 0A ~ 40A (Skond il-mudell), Il-massimu | 0A ~ 20A (Skond il-mudell), Il-qawwa massima tal-iċċarġjar hija 1/4 tal-qawwa nominali) | ||||
Kurrent tal-iċċarġjar tal-kontrollur solari inkorporat (mhux obbligatorju) | PWM:(48V:120A;96V:50A/100A;192V/384V:50A) MPPT:(48V:100A/200A;96V:50A/100A;192V/384V:50A) | 50A/100A | ||||
Daqs (L * W * Hmm) | 540x350x695 | 593x370x820 | ||||
Daqs tal-ippakkjar (L * W * Hmm) | 600 * 410 * 810 | 656*420*937 | ||||
NW(kg) | 66 | 70 | 77 | 110 | 116 | |
GW (kg) | 77 | 81 | 88 | 124 | 130 | |
Metodu ta 'Installazzjoni | Torri | |||||
Input | Medda tal-Vultaġġ tad-Dħul DC | 10.5-15VDC (Vultaġġ tal-batterija waħda) | ||||
Medda ta 'Vultaġġ ta' Input AC | 73VAC~138VAC(110VAC) / 83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) / 155VAC~285VAC(230VAC(230VAC)/165VAC~2)VAC0(275VAC0(220VAC) ~ 7000W) | |||||
Firxa tal-Frekwenzi tad-Dħul AC | 45Hz~55Hz(50Hz)/55Hz~65Hz(60Hz) | |||||
Metodu ta 'ċċarġjar AC | Tliet stadji (kurrent kostanti, vultaġġ kostanti, ħlas f'wiċċ l-ilma) | |||||
Output | Effiċjenza (Modalità Batterija) | ≥85% | ||||
Vultaġġ tal-Ħruġ (Modalità tal-Batterija) | 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | |||||
Frekwenza tal-Ħruġ (Modalità tal-Batterija) | 50Hz±0.5 jew 60Hz±0.5 | |||||
Mewġ tal-Ħruġ (Modalità tal-Batterija) | Mewġa Sinus pura | |||||
Effiċjenza (Modalità AC) | >99% | |||||
Vultaġġ tal-Ħruġ (Modalità AC) | Segwi l-input | |||||
Frekwenza tal-Ħruġ (Modalità AC) | Traċċar Awtomatikament | |||||
Distorsjoni tal-forma tal-mewġ tal-ħruġ (Modalità Batterija) | ≤3% (tagħbija lineari) | |||||
Ebda telf ta' tagħbija (Modalità Batterija) | ≤1% qawwa nominali | |||||
Ebda telf ta 'tagħbija (Modalità AC) | ≤2% qawwa nominali (ċarġer ma jaħdimx fil-modalità AC) | |||||
Ebda telf ta 'tagħbija (Modalità li tiffranka l-enerġija) | ≤10W | |||||
Tip ta batterija | Batterija VRLA | Vultaġġ ta 'ċarġ: 14.2V;Vultaġġ Float: 13.8V (vultaġġ tal-batterija waħda) | ||||
Ippersonalizza l-batterija | Il-parametri tal-iċċarġjar u l-ħatt ta 'tipi differenti ta' batteriji jistgħu jiġu personalizzati skont ir-rekwiżiti tal-utent | |||||
Protezzjoni | Allarm ta 'vultaġġ baxx tal-batterija | Default tal-fabbrika: 11V (Vultaġġ tal-batterija waħda) | ||||
Protezzjoni taħt il-vultaġġ tal-batterija | Default tal-fabbrika: 10.5V (Vultaġġ tal-batterija waħda) | |||||
Allarm ta 'vultaġġ żejjed tal-batterija | Default tal-fabbrika: 15V (Vultaġġ tal-batterija waħda) | |||||
Protezzjoni ta 'vultaġġ żejjed tal-batterija | Default tal-fabbrika: 17V (Vultaġġ tal-batterija waħda) | |||||
Vultaġġ ta 'rkupru ta' vultaġġ żejjed tal-batterija | Default tal-fabbrika: 14.5V (Vultaġġ tal-batterija waħda) | |||||
Protezzjoni ta 'qawwa ta' tagħbija żejda | Protezzjoni awtomatika (mod tal-batterija), circuit breaker jew assigurazzjoni (modalità AC) | |||||
Protezzjoni ta 'short circuit tal-output tal-inverter | Protezzjoni awtomatika (mod tal-batterija), circuit breaker jew assigurazzjoni (modalità AC) | |||||
Protezzjoni tat-temperatura | >90°C (Itfi l-output) | |||||
Allarm | A | Kondizzjoni normali tax-xogħol, buzzer m'għandu l-ebda ħoss ta 'allarm | ||||
B | Buzzer ħsejjes 4 darbiet kull sekonda meta ħsara fil-batterija, anormalità tal-vultaġġ, protezzjoni ta 'tagħbija żejda | |||||
C | Meta l-magna tinxtegħel għall-ewwel darba, il-buzzer iħeġġeġ 5 meta l-magna tkun normali | |||||
Ġewwa l-kontrollur solari | Modalità tal-Iċċarġjar | PWM jew MPPT | ||||
Medda ta 'Vultaġġ ta' Input PV | PWM: 15V-44V(sistema 12V);30V-44V(sistema 24V);60V-88V(48V sistema);120V-176V (sistema 96V);240V-352V (sistema 192V) ;300V-400V (sistema 240V); 480V-704V (sistema 384V) | |||||
Vultaġġ ta' Input Max PV (Voc) | PWM: 50V(sistema 12V/24V);100V(48V sistema);200V (sistema 96V);400V (sistema 192V);500V (sistema 240V); 750V (sistema 384V) | |||||
PV Array Enerġija Massima | Sistema 12V: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A); | |||||
Telf standby | ≤3W | |||||
Effiċjenza massima ta 'konverżjoni | >95% | |||||
Modalità tax-Xogħol | Battery First/AC First/Modalità Iffrankar tal-Enerġija | |||||
Ħin tat-Trasferiment | ≤4ms | |||||
Wiri | LCD | |||||
Metodu termali | Fann li jkessaħ f'kontroll intelliġenti | |||||
Komunikazzjoni (Mhux obbligatorju) | RS485/APP (monitoraġġ WIFI jew monitoraġġ GPRS) | |||||
Ambjent | Temperatura operattiva | -10 ℃ ~ 40 ℃ | ||||
Temperatura tal-ħażna | -15 ℃ ~ 60 ℃ | |||||
Storbju | ≤55dB | |||||
Elevazzjoni | 2000m (Iktar minn derating) | |||||
Umdità | 0% ~ 95%, L-ebda kondensazzjoni |
Mudell DKWD | 35248/96 (352) | 40248/96(402) | 50248/96(502) | 60248/96(602) | 70248/96/192(702) | |
Qawwa Rated | 3500W | 4000W | 5000W | 6000W | 7000W | |
L-ogħla qawwa (20 ms) | 10500VA | 12000VA | 15000VA | 18000VA | 21000VA | |
Ibda bil-Mutur | 3HP | 3HP | 4HP | 4HP | 5HP | |
Vultaġġ tal-batterija | 48/96VDC | 48/96VDC | 48/96VDC | 48/96VDC | 48/96/192VDC | |
Max AC iċċarġjar kurrenti | 0A ~ 20A (Skond il-mudell), Il-qawwa massima tal-iċċarġjar hija 1/4 tal-qawwa nominali) | |||||
Kurrent tal-iċċarġjar tal-kontrollur solari inkorporat (mhux obbligatorju) | 24/48V(PWM:10A~60A/MPPT:10A~100A) | 48V(PWM:10A~120A/MPPT:10A~100A) / | ||||
Daqs (L * W * Hmm) | 410x200x350 | 491x260x490 | ||||
Daqs tal-ippakkjar (L * W * Hmm) | 475x265x410 | 545x315x550 | ||||
NW(kg) | 21.5 | 29 | 30 | 31.5 | 36 | |
GW (kg) | 23.5 | 32 | 33 | 34.5 | 39 | |
Metodu ta 'Installazzjoni | Torri | |||||
Mudell DKWD | 253240 | 303240 | 403384 | |||
Qawwa Rated | 25KW | 30KW | 40KW | |||
L-ogħla qawwa (20 ms) | 75KVA | 90KVA | 120KVA | |||
Ibda bil-Mutur | 15HP | 15HP | 20HP | |||
Vultaġġ tal-batterija | 240VDC | 240VDC | 384VDC | |||
Max AC iċċarġjar kurrenti | 0A ~ 20A (Skond il-mudell), Il-qawwa massima tal-iċċarġjar hija 1/4 tal-qawwa nominali) | |||||
Kurrent tal-iċċarġjar tal-kontrollur solari inkorporat (mhux obbligatorju) | 50A/100A | 50A/100A | ||||
Daqs (L * W * Hmm) | 593x370x820 | 721x400x1002 | ||||
Daqs tal-ippakkjar (L * W * Hmm) | 656*420*937 | 775x465x1120 | ||||
NW(kg) | 123 | 167 | 192 | |||
GW (kg) | 137 | 190 | 215 | |||
Metodu ta 'Installazzjoni | Torri | |||||
Input | Medda tal-Vultaġġ tad-Dħul DC | 10.5-15VDC (Vultaġġ tal-batterija waħda) | ||||
Medda ta 'Vultaġġ ta' Input AC | 73VAC~138VAC(110VAC) / 83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) / 155VAC~285VAC(230VAC(230VAC)/165VAC~2)VAC0(275VAC0(220VAC) ~ 7000W) | |||||
Firxa tal-Frekwenzi tad-Dħul AC | 45Hz~55Hz(50Hz)/55Hz~65Hz(60Hz) | |||||
Metodu ta 'ċċarġjar AC | Tliet stadji (kurrent kostanti, vultaġġ kostanti, ħlas f'wiċċ l-ilma) | |||||
Output | Effiċjenza (Modalità Batterija) | ≥85% | ||||
Vultaġġ tal-Ħruġ (Modalità tal-Batterija) | 110VAC±2% / 120VAC±2% / 220VAC±2% / 230VAC±2% / 240VAC±2% | |||||
Frekwenza tal-Ħruġ (Modalità tal-Batterija) | 50Hz±0.5 jew 60Hz±0.5 | |||||
Mewġ tal-Ħruġ (Modalità tal-Batterija) | Mewġa Sinus pura | |||||
Effiċjenza (Modalità AC) | >99% | |||||
Vultaġġ tal-Ħruġ (Modalità AC) | Segwi l-input | |||||
Frekwenza tal-Ħruġ (Modalità AC) | Traċċar Awtomatikament | |||||
Distorsjoni tal-forma tal-mewġ tal-ħruġ (Modalità Batterija) | ≤3% (tagħbija lineari) | |||||
Ebda telf ta' tagħbija (Modalità Batterija) | ≤1% qawwa nominali | |||||
Ebda telf ta 'tagħbija (Modalità AC) | ≤2% qawwa nominali (ċarġer ma jaħdimx fil-modalità AC) | |||||
Ebda telf ta 'tagħbija (Modalità li tiffranka l-enerġija) | ≤10W | |||||
Tip ta batterija | Batterija VRLA | Vultaġġ ta 'ċarġ: 14.2V;Vultaġġ Float: 13.8V (vultaġġ tal-batterija waħda) | ||||
Ippersonalizza l-batterija | Il-parametri tal-iċċarġjar u l-ħatt ta 'tipi differenti ta' batteriji jistgħu jiġu personalizzati skont ir-rekwiżiti tal-utent | |||||
Protezzjoni | Allarm ta 'vultaġġ baxx tal-batterija | Default tal-fabbrika: 11V (Vultaġġ tal-batterija waħda) | ||||
Protezzjoni taħt il-vultaġġ tal-batterija | Default tal-fabbrika: 10.5V (Vultaġġ tal-batterija waħda) | |||||
Allarm ta 'vultaġġ żejjed tal-batterija | Default tal-fabbrika: 15V (Vultaġġ tal-batterija waħda) | |||||
Protezzjoni ta 'vultaġġ żejjed tal-batterija | Default tal-fabbrika: 17V (Vultaġġ tal-batterija waħda) | |||||
Vultaġġ ta 'rkupru ta' vultaġġ żejjed tal-batterija | Default tal-fabbrika: 14.5V (Vultaġġ tal-batterija waħda) | |||||
Protezzjoni ta 'qawwa ta' tagħbija żejda | Protezzjoni awtomatika (mod tal-batterija), circuit breaker jew assigurazzjoni (modalità AC) | |||||
Protezzjoni ta 'short circuit tal-output tal-inverter | Protezzjoni awtomatika (mod tal-batterija), circuit breaker jew assigurazzjoni (modalità AC) | |||||
Protezzjoni tat-temperatura | >90°C (Itfi l-output) | |||||
Allarm | A | Kondizzjoni normali tax-xogħol, buzzer m'għandu l-ebda ħoss ta 'allarm | ||||
B | Buzzer ħsejjes 4 darbiet kull sekonda meta ħsara fil-batterija, anormalità tal-vultaġġ, protezzjoni ta 'tagħbija żejda | |||||
C | Meta l-magna tinxtegħel għall-ewwel darba, il-buzzer iħeġġeġ 5 meta l-magna tkun normali | |||||
Ġewwa l-kontrollur solari | Modalità tal-Iċċarġjar | PWM jew MPPT | ||||
Medda ta 'Vultaġġ ta' Input PV | PWM: 15V-44V(sistema 12V);30V-44V(sistema 24V);60V-88V(48V sistema);120V-176V (sistema 96V);240V-352V (sistema 192V) ;300V-400V (sistema 240V); 480V-704V (sistema 384V) | |||||
Vultaġġ ta' Input Max PV (Voc) | PWM: 50V(sistema 12V/24V);100V(48V sistema);200V (sistema 96V);400V (sistema 192V);500V (sistema 240V); 750V (sistema 384V) | |||||
PV Array Enerġija Massima | Sistema 12V: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A); | |||||
Telf standby | ≤3W | |||||
Effiċjenza massima ta 'konverżjoni | >95% | |||||
Modalità tax-Xogħol | Battery First/AC First/Modalità Iffrankar tal-Enerġija | |||||
Ħin tat-Trasferiment | ≤4ms | |||||
Wiri | LCD | |||||
Metodu termali | Fann li jkessaħ f'kontroll intelliġenti | |||||
Komunikazzjoni (Mhux obbligatorju) | RS485/APP (monitoraġġ WIFI jew monitoraġġ GPRS) | |||||
Ambjent | Temperatura operattiva | -10 ℃ ~ 40 ℃ | ||||
Temperatura tal-ħażna | -15 ℃ ~ 60 ℃ | |||||
Storbju | ≤55dB | |||||
Elevazzjoni | 2000m (Iktar minn derating) | |||||
Umdità | 0% ~ 95%, L-ebda kondensazzjoni |
X'servizz noffru?
1. Servizz ta 'disinn.
Sempliċement għarrafna l-karatteristiċi li trid, bħar-rata tal-enerġija, l-applikazzjonijiet li trid tagħbija, kemm għandek bżonn is-sistema biex taħdem eċċ Aħna ser niddisinjaw sistema ta 'enerġija solari raġonevoli għalik.
Aħna se nagħmlu dijagramma tas-sistema u l-konfigurazzjoni dettaljata.
2. Servizzi ta' Offerti
Jgħin lill-mistednin fit-tħejjija tad-dokumenti tal-offerti u d-dejta teknika
3. Servizz ta 'taħriġ
Jekk inti wieħed ġdid fin-negozju tal-ħażna tal-enerġija, u għandek bżonn ta 'taħriġ, tista' tiġi l-kumpanija tagħna biex titgħallem jew nibagħtu tekniċi biex jgħinuk tħarreġ l-għalf tiegħek.
4. Servizz ta 'immuntar u servizz ta' manutenzjoni
Noffru wkoll servizz ta 'immuntar u servizz ta' manutenzjoni bi spiża staġjonali u affordabbli.
5. Appoġġ għall-kummerċjalizzazzjoni
Aħna nagħtu appoġġ kbir lill-klijenti li l-aġent tad-ditta tagħna "Dking power".
aħna nibagħtu inġiniera u tekniċi biex jappoġġjawk jekk meħtieġ.
aħna nibagħtu ċerti fil-mija partijiet żejda ta 'wħud mill-prodotti bħala sostituzzjonijiet liberament.
X'inhi s-sistema ta 'enerġija solari minima u massima li tista' tipproduċi?
Is-sistema minima ta 'enerġija solari li pproduċejna hija ta' madwar 30w, bħal dawl tat-toroq solari.Imma normalment il-minimu għall-użu fid-dar huwa 100w 200w 300w 500w eċċ.
Ħafna nies jippreferu 1kw 2kw 3kw 5kw 10kw eċċ għall-użu fid-dar, normalment huwa AC110v jew 220v u 230v.
Is-sistema ta 'enerġija solari max li pproduċejna hija 30MW/50MWH.
Kif inhi l-kwalità tiegħek?
Il-kwalità tagħna hija għolja ħafna, għaliex nużaw materjali ta 'kwalità għolja ħafna u nagħmlu testijiet rigorużi tal-materjali.U għandna sistema ta 'QC stretta ħafna.
Taċċetta produzzjoni apposta?
Iva.għidilna biss dak li trid.Aħna personalizzati lR&D u nipproduċu batteriji tal-litju tal-ħażna tal-enerġija, batteriji tal-litju b'temperatura baxxa, batteriji tal-litju tal-mottiv, batteriji tal-litju tal-vetturi off highway, sistemi tal-enerġija solari eċċ.
X'inhu l-ħin taċ-ċomb?
Normalment 20-30 jum
Kif tiggarantixxi l-prodotti tiegħek?
Matul il-perjodu tal-garanzija, jekk hija r-raġuni tal-prodott, aħna nibagħtulek sostituzzjoni tal-prodott.Uħud mill-prodotti aħna nibagħtulek wieħed ġdid bit-tbaħħir li jmiss.Prodotti differenti b'termini ta 'garanzija differenti.Iżda qabel ma nibagħtu, għandna bżonn stampa jew vidjo biex niżguraw li hija l-problema tal-prodotti tagħna.
workshops
Każijiet
400KWH (192V2000AH Lifepo4 u sistema ta 'ħażna ta' enerġija solari fil-Filippini)
200KW PV + 384V1200AH (500KWH) sistema ta 'ħażna ta' enerġija tal-batterija solari u tal-litju fin-Niġerja
400KW PV + 384V2500AH (1000KWH) sistema ta 'ħażna ta' enerġija tal-batterija solari u tal-litju fl-Amerika.